Releasenotes

MT52 USB Firmware

Alle einblenden
Alle ausblenden
  • MT52 USB v4.08

    v4.08

    • Bugfixing: The selection of the connected Bluetooth printer was lost

    v4.07

    • Bugfixing: printer timings corrected

    v4.06

    • Bugfix: When disconnecting and reconnecting the USB cable, it was no longer possible to connect to the MT52. This version corrects the initialization of the USB interface after reconnecting the USB cable.
    • Pulsation graph moved for better visualtion of curves >45kPa
    • MT52 USB v4.05

      v4.05

      • This version supports now also the Milkotest MT52 with bluetooth interface
      • Bugfixing: cluster table missed in the ISOa print out
      • some text correction added

      v4.04

      • Bugfixing: the directories disappeared during navigation
      • Bugfixing: the device standby blocked the measurements

      v4.03

      • Reading ISO reports from the Explorer
      • Memory optimizations

      v4.01, v4.02

      • Bugfixing in menu navigation

      v4.00

      • first version with the new Data Explorer
      • MT52 USB v3.39

        • first version which supports the Milkotest MT52 with bluetooth interface
        • MT52 USB v3.36

          v3.35

          • Bugfixing: holding the standby while charging

          v3.36

          • some approvments in the menu navigation for the Logimat report

          MT52 PC Software

          Alle einblenden
          Alle ausblenden
          • MT52 PC Software v4.0.1.1

              v4.0.4.1

              • WebApp (experimental function) default deactivated

              v4.0.3.2

              • Bugfixing in SSL certificates verification

              v4.0.1.5

              • Online licencing function added

              v4.0.1.2

              • Connection to WebApp  added

              v4.0.0.0

              • first Version which supports the new Data Explorer
              • MT52 PC Software v3.11.1.4

                  v3.11.1.4

                    • Bugfixing

                    v3.10.3.1

                    • Bugfixing: old file version was used for saving MilkingTime Test measurements
                    • When starting the software, the connection to the Milkotest is checked only once

                    v3.10.0.1

                    • Added an input form for the Logimat report
                    • MT52 PC Software v3.9.0.1

                        • Logimat Funktionen added
                        • Program desing reviesed
                        • To open saved files, it is no longer necessary to select the corresponding program first. The correct program is selected based on the selected file.
                        • RunTime Engine to 2014.1 updated
                        • MT52 PC Software v3.6.5.1

                            • Italienische language added.
                            • MT52 PC Software v1.34r2:

                              • COM-Port enabled have not been set correctly
                              • the Licence File have not been written

                            MT52 Firmware

                            Alle einblenden
                            Alle ausblenden
                            • MT52 Firmware 2.13 A1 .. B2

                              • Anpassungen WGM und CH Protokoll
                              • Support für neue Drucksensoren
                            • MT52 Firmware 2.13 C1

                              • Logimat Support added
                              • ISO report can now be done without AFM